Products
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Rtx-1 GC Columns
-
Rtx-1 PONA GC Columns
-
Rtx-1ms GC Columns
-
Rtx-5 GC Columns
-
Rtx-5 Amine GC Columns
-
Rtx-5 DHA GC Columns
-
Rtx-5MS GC Columns
-
Rtx-5Sil MS GC Columns
-
Rtx-20 GC Columns
-
Rtx-35 GC Columns
-
Rtx-35 Amine GC Columns
-
Rtx-35MS GC Columns
-
Rtx-50 GC Columns
-
Rtx-65 GC Columns
-
Rtx-65TG GC Columns
-
Rtx-200 GC Columns
-
Rtx-200MS GC Columns
-
Rtx-225 GC Columns
-
Rtx-440 GC Columns
-
Rtx-502.2 GC Columns
-
Rtx-624 GC Columns
-
Rtx-1301 GC Columns
-
Rtx-1614 GC Columns
-
Rtx-1701 GC Columns
-
Rtx-2330 GC Columns
-
Rtx-2887 GC Columns
-
Rtx-BAC1 GC Columns
-
Rtx-BAC2 GC Columns
-
Rtx-BAC Plus 1 GC Columns
-
Rtx-BAC Plus 2 GC Columns
-
Rtx-Biodiesel TG GC Columns
-
Rtx-CLPesticides GC Columns
-
Rtx-CLPesticides2 GC Columns
-
Rtx-DHA GC Columns
-
Rtx-Dioxin2 GC Columns
-
Rtx-Mineral Oil GC Columns
-
Rtx-OPPesticides GC Columns
-
Rtx-OPPesticides2 GC Columns
-
Rtx-PCB GC Columns
-
Rtx-TNT1 GC Columns
-
Rtx-TNT2 GC Columns
-
Rtx-VMS GC Columns
-
Rtx-VRX GC Columns
-
Rtx-Volatile Amine GC Columns
-
Rtx-Volatiles GC Columns
-
Rtx-Wax GC Columns
-
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Restek MXT GC Columns
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Trademarks
-
Catalogs & Downloads
-
Outlet
-
Troubleshooting
Rtx-Dioxin2 GC Columns
Designed specifically for ultra-trace dioxin and furan analysis, the Rtx-Dioxin2 column combines exceptional thermal stability with highly selective isomer separation. Its proprietary stationary phase provides confirmation-level selectivity for both tetrachlorodibenzo-p-dioxins (TCDDs) and tetrachlorodibenzofurans (TCDFs), allowing laboratories to simplify analytical workflows while maintaining confidence in regulatory results.
- Application-specific column for toxic dioxin and furan congener analysis.
- Achieves isomer-specific separation of both 2,3,7,8-TCDD and 2,3,7,8-TCDF using a single GC column.
- Unique selectivity makes it an ideal confirmation column for EPA Method 1613 and related dioxin methods.
- Excellent resolution minimizes interference from closely eluting congeners, improving identification accuracy and reducing confirmation complexity.
- High thermal stability up to 340 °C enables faster bake-out, lower column bleed, and extended operational lifetime.
- Supports higher laboratory throughput by reducing column changes, instrument downtime, and separate confirmation analyses.
Similar Phases:
No direct equivalent available.
Filter products
3 Products
Rtx-Dioxin2, 40m x 0.18mm ID, 0.18µm film, ea.
Restek GC Column Rtx-Dioxin2, 40 m x 0.18 mm ID, 0.18 µm film thickness, ea.
Art.-Nr.: RT-10759
EUR 1,084.00
Will be procured as soon as possible
Rtx-Dioxin2, 60m x 0.25mm ID, 0.25µm film, ea.
Restek GC Column Rtx-Dioxin2, 60 m x 0.25 mm ID, 0.25 µm film thickness, ea.
Art.-Nr.: RT-10758
EUR 1,245.00
Will be procured as soon as possible
Rtx-Dioxin2, 60m x 0.25mm ID, 0.25µm film, pk.6
Restek GC Column Rtx-Dioxin2, 60 m x 0.25 mm ID, 0.25 µm film thickness, pk.6
Art.-Nr.: RT-10758-600
Price on request
Will be procured as soon as possible