-
Produits
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Restek MXT GC Columns
-
MXT-1 GC Columns
-
MXT-1HT SimDist GC Columns
-
MXT-5 GC Columns
-
MXT-20 GC Columns
-
MXT-35 GC Columns
-
MXT-50 GC Columns
-
MXT-65 GC Columns
-
MXT-65TG GC Columns
-
MXT-200 GC Columns
-
MXT-502.2 GC Columns
-
MXT-1301 GC Columns
-
MXT-1701 GC Columns
-
MXT-2887 GC Columns
-
MXT-Alumina BOND/MAPD PLOT GC Columns
-
MXT-Alumina BOND/Na2SO4 PLOT GC Columns
-
MXT-BAC1 GC Columns
-
MXT-Biodiesel TG GC Columns
-
MXT-Msieve 5A PLOT GC Columns
-
MXT-Q-BOND PLOT GC Columns
-
MXT-Volatiles GC Columns
-
MXT-WAX GC Columns
-
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Marques déposées
-
Catalogues & téléchargements
-
Fin de série
-
Troubleshooting
MXT-Alumina BOND/Na2SO4 PLOT GC Columns
The Restek MXT-Alumina BOND/Na₂SO₄ is engineered for high-performance C1–C5 hydrocarbon and halocarbon analyses in demanding refinery, process, and field GC applications. Its optimized Na₂SO₄-deactivated alumina stationary phase provides excellent selectivity for saturated and unsaturated hydrocarbon isomers while delivering highly reproducible retention and quantitative performance. Manufactured from Siltek®-treated stainless steel tubing, it combines outstanding mechanical durability with the ruggedness required for continuous industrial operation.
- Recommended for the purity analysis of C1–C5 hydrocarbons, including ethylene, propylene, butenes, and halocarbons.
- Provides excellent separation of butene isomers, making it ideal for impurity analysis in butene process streams.
- Na₂SO₄-deactivated alumina stationary phase minimizes surface reactivity, improving response for polar unsaturated hydrocarbons, such as dienes.
- Delivers excellent sensitivity with linear, quantitative chromatographic performance for saturated and unsaturated hydrocarbon isomers.
- High sample capacity produces sharp, symmetrical peaks, making the column suitable for both major component analysis and ppm-level impurity determinations.
- Stable to 200 °C and can be regenerated by conditioning at the maximum operating temperature following moisture exposure.
- Manufactured from Siltek®-treated stainless steel tubing, offering exceptional resistance to shock and rough handling for demanding field and process GC environments.
- Available in compact 3.5-inch coil or 7-inch, 11-pin cage configurations for installations where space is limited.
- Every column is individually tested to ensure reproducible retention times, predictable flow characteristics, and consistent chromatographic performance.
Similar Phases:
CP-Al₂O₃/Na₂SO₄
Filtre
1 Produits
MXT-Alumina BOND/Na2SO4, 30m x 0.53mm ID, 10µm film, ea.
Restek GC Column MXT-Alumina BOND/Na2SO4, 30 m x 0.53 mm ID, 10 µm film thickness, ea.
Art.-Nr.: RT-79714
EUR 1,124.00
En cours de réapprovisionnement