-
Products
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Rtx-1 GC Columns
-
Rtx-1 PONA GC Columns
-
Rtx-1ms GC Columns
-
Rtx-5 GC Columns
-
Rtx-5 Amine GC Columns
-
Rtx-5 DHA GC Columns
-
Rtx-5MS GC Columns
-
Rtx-5Sil MS GC Columns
-
Rtx-20 GC Columns
-
Rtx-35 GC Columns
-
Rtx-35 Amine GC Columns
-
Rtx-35MS GC Columns
-
Rtx-50 GC Columns
-
Rtx-65 GC Columns
-
Rtx-65TG GC Columns
-
Rtx-200 GC Columns
-
Rtx-200MS GC Columns
-
Rtx-225 GC Columns
-
Rtx-440 GC Columns
-
Rtx-502.2 GC Columns
-
Rtx-624 GC Columns
-
Rtx-1301 GC Columns
-
Rtx-1614 GC Columns
-
Rtx-1701 GC Columns
-
Rtx-2330 GC Columns
-
Rtx-2887 GC Columns
-
Rtx-BAC1 GC Columns
-
Rtx-BAC2 GC Columns
-
Rtx-BAC Plus 1 GC Columns
-
Rtx-BAC Plus 2 GC Columns
-
Rtx-Biodiesel TG GC Columns
-
Rtx-CLPesticides GC Columns
-
Rtx-CLPesticides2 GC Columns
-
Rtx-DHA GC Columns
-
Rtx-Dioxin2 GC Columns
-
Rtx-Mineral Oil GC Columns
-
Rtx-OPPesticides GC Columns
-
Rtx-OPPesticides2 GC Columns
-
Rtx-PCB GC Columns
-
Rtx-TNT1 GC Columns
-
Rtx-TNT2 GC Columns
-
Rtx-VMS GC Columns
-
Rtx-VRX GC Columns
-
Rtx-Volatile Amine GC Columns
-
Rtx-Volatiles GC Columns
-
Rtx-Wax GC Columns
-
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Restek MXT GC Columns
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Trademarks
-
Catalogs & Downloads
-
Outlet
-
Troubleshooting
- Purpose-built for volatile amines in water and other challenging matrices, delivering complete baseline resolution with excellent selectivity, highly symmetrical peak shapes, and outstanding sensitivity for primary, secondary, tertiary amines and free ammonia.
- A highly robust bonded stationary phase withstands repeated water injections while maintaining exceptional inertness, long column lifetime, and consistent chromatographic performance. Every column is individually qualified using a dedicated amine test mixture to verify reproducibility, reliability, and quantitative accuracy.
- Thermal stability up to 290 °C enables efficient elution of amines through C16 while allowing high-temperature bake-out to remove accumulated contaminants and extend operational lifetime.
Filter products
Art.-Nr.: RT-18076
Will be procured as soon as possible
Art.-Nr.: RT-18076-104
Will be procured as soon as possible
Art.-Nr.: RT-18077
Will be procured as soon as possible
Art.-Nr.: RT-18077-289
Will be procured as soon as possible
Art.-Nr.: RT-18077-6850
Will be procured as soon as possible
Art.-Nr.: RT-18078
Will be procured as soon as possible
Art.-Nr.: RT-18078-115
Will be procured as soon as possible
Art.-Nr.: RT-18078-600
Will be procured as soon as possible
Art.-Nr.: RT-18078-6850
Will be procured as soon as possible