Products
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Rtx-1 GC Columns
-
Rtx-1 PONA GC Columns
-
Rtx-1ms GC Columns
-
Rtx-5 GC Columns
-
Rtx-5 Amine GC Columns
-
Rtx-5 DHA GC Columns
-
Rtx-5MS GC Columns
-
Rtx-5Sil MS GC Columns
-
Rtx-20 GC Columns
-
Rtx-35 GC Columns
-
Rtx-35 Amine GC Columns
-
Rtx-35MS GC Columns
-
Rtx-50 GC Columns
-
Rtx-65 GC Columns
-
Rtx-65TG GC Columns
-
Rtx-200 GC Columns
-
Rtx-200MS GC Columns
-
Rtx-225 GC Columns
-
Rtx-440 GC Columns
-
Rtx-502.2 GC Columns
-
Rtx-624 GC Columns
-
Rtx-1301 GC Columns
-
Rtx-1614 GC Columns
-
Rtx-1701 GC Columns
-
Rtx-2330 GC Columns
-
Rtx-2887 GC Columns
-
Rtx-BAC1 GC Columns
-
Rtx-BAC2 GC Columns
-
Rtx-BAC Plus 1 GC Columns
-
Rtx-BAC Plus 2 GC Columns
-
Rtx-Biodiesel TG GC Columns
-
Rtx-CLPesticides GC Columns
-
Rtx-CLPesticides2 GC Columns
-
Rtx-DHA GC Columns
-
Rtx-Dioxin2 GC Columns
-
Rtx-Mineral Oil GC Columns
-
Rtx-OPPesticides GC Columns
-
Rtx-OPPesticides2 GC Columns
-
Rtx-PCB GC Columns
-
Rtx-TNT1 GC Columns
-
Rtx-TNT2 GC Columns
-
Rtx-VMS GC Columns
-
Rtx-VRX GC Columns
-
Rtx-Volatile Amine GC Columns
-
Rtx-Volatiles GC Columns
-
Rtx-Wax GC Columns
-
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Restek MXT GC Columns
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Trademarks
-
Catalogs & Downloads
-
Outlet
-
Troubleshooting
Rtx-TNT1 GC Columns
Explosives analysis demands uncompromising chromatographic resolution, especially when trace-level nitroaromatic compounds must be identified with confidence. Rtx-TNT was purpose-developed for U.S. EPA Method 8095, combining a proprietary stationary phase with low-bleed performance to deliver fast, reliable separations by GC-ECD or GC-MS. Its optimized selectivity enables accurate determination of explosive residues while maintaining the robustness required for routine forensic and environmental laboratories.
- Application-specific column optimized for nitroaromatic explosives and U.S. EPA Method 8095.
- Provides excellent resolution of the 16 target analytes defined in EPA Method 8095.
- Low-bleed stationary phase is ideally suited for high-sensitivity GC-ECD and GC-MS analyses.
- Complete chromatographic separation can be achieved in less than 20 minutes, improving laboratory throughput.
- Higher thermal stability than conventional explosive-analysis columns allows efficient bake-out and longer operational lifetime.
- Designed to operate under identical temperature programs with the complementary Rtx-TNT2 confirmation column.
Similar Phases:
No direct equivalent. Proprietary Restek stationary phase
Filter products
1 Products
Rtx-TNT1, 6m x 0.53mm ID, 1.50µm film, pk.3
Restek GC Column Rtx-TNT1, 6 m x 0.53 mm ID, 1.50 µm film thickness, pk.3
Art.-Nr.: RT-12998
EUR 627.00
Will be procured as soon as possible