-
Products
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Rt-Alumina BOND/CFC GC Columns
-
Rt-Alumina BOND/MAPD GC Columns
-
Rt-Alumina BOND/KCl GC Columns
-
Rt-Alumina BOND/Na2SO4 GC Columns
-
Rt-Msieve 5A GC Columns
-
Rt-Q-BOND GC Columns
-
Rt-QS-BOND GC Columns
-
Rt-S-BOND GC Columns
-
Rt-U-BOND GC Columns
-
Rt-U-BOND XP GC Columns
-
MXT-Alumina BOND/MAPD PLOT GC Columns
-
MXT-Alumina BOND/Na2SO4 PLOT GC Columns
-
MXT-Msieve 5A PLOT GC Columns
-
MXT-Q-BOND PLOT GC Columns
-
-
Restek MXT GC Columns
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Trademarks
-
Catalogs & Downloads
-
Outlet
-
Troubleshooting
- Specifically developed for the trace analysis of methyl acetylene, propadiene, and acetylene in petrochemical and refinery process streams.
- Optimized alumina deactivation maximizes response for polar hydrocarbons while providing excellent reproducibility for quantitative process applications where recalibration should be minimized.
- Ideal for the analysis of ethylene, propylene, butylenes, butadiene, and other downstream petrochemical products.
- High sample loading capacity minimizes peak tailing and improves the separation of trace impurities from major hydrocarbon components.
- Extended 250 °C operating temperature enables rapid elution of higher molecular weight hydrocarbons, including compounds up to dodecane, while reducing regeneration time following exposure to moisture.
- Strongly bonded alumina layer minimizes particle release, supporting reliable valve switching and helping protect injection and detection systems.
- Each column is individually tested for retention, selectivity, efficiency, and reproducible flow characteristics to ensure consistent column-to-column performance.
- Available on fused silica tubing, with selected dimensions also offered in robust MXT-Alumina metal columns.
Filter products
Art.-Nr.: RT-19781
Will be procured as soon as possible
Art.-Nr.: RT-19779
Will be procured as soon as possible
Art.-Nr.: RT-19780
Will be procured as soon as possible
Art.-Nr.: RT-19777
Will be procured as soon as possible
Art.-Nr.: RT-19778
Will be procured as soon as possible