-
Ürünlerimiz
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Rtx-1 GC Columns
-
Rtx-1 PONA GC Columns
-
Rtx-1ms GC Columns
-
Rtx-5 GC Columns
-
Rtx-5 Amine GC Columns
-
Rtx-5 DHA GC Columns
-
Rtx-5MS GC Columns
-
Rtx-5Sil MS GC Columns
-
Rtx-20 GC Columns
-
Rtx-35 GC Columns
-
Rtx-35 Amine GC Columns
-
Rtx-35MS GC Columns
-
Rtx-50 GC Columns
-
Rtx-65 GC Columns
-
Rtx-65TG GC Columns
-
Rtx-200 GC Columns
-
Rtx-200MS GC Columns
-
Rtx-225 GC Columns
-
Rtx-440 GC Columns
-
Rtx-502.2 GC Columns
-
Rtx-624 GC Columns
-
Rtx-1301 GC Columns
-
Rtx-1614 GC Columns
-
Rtx-1701 GC Columns
-
Rtx-2330 GC Columns
-
Rtx-2887 GC Columns
-
Rtx-BAC1 GC Columns
-
Rtx-BAC2 GC Columns
-
Rtx-BAC Plus 1 GC Columns
-
Rtx-BAC Plus 2 GC Columns
-
Rtx-Biodiesel TG GC Columns
-
Rtx-CLPesticides GC Columns
-
Rtx-CLPesticides2 GC Columns
-
Rtx-DHA GC Columns
-
Rtx-Dioxin2 GC Columns
-
Rtx-Mineral Oil GC Columns
-
Rtx-OPPesticides GC Columns
-
Rtx-OPPesticides2 GC Columns
-
Rtx-PCB GC Columns
-
Rtx-TNT1 GC Columns
-
Rtx-TNT2 GC Columns
-
Rtx-VMS GC Columns
-
Rtx-VRX GC Columns
-
Rtx-Volatile Amine GC Columns
-
Rtx-Volatiles GC Columns
-
Rtx-Wax GC Columns
-
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Restek MXT GC Columns
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Markalar
-
Katalog & İndirmeler
-
Fırsat Ürünleri
-
Troubleshooting
6% Cyanopropylphenyl / 94% Dimethyl Polysiloxane
- Application-specific column for volatile organic pollutants (VOCs) in environmental analyses.
- Recommended for US EPA Methods 524.2, 8260, 624, 8240 and other VOC methods.
- Provides greater than 90% resolution of the first six gases in EPA Methods 524.2 and 8260 without subambient cooling (105 m columns).
- Superior resolution of early-eluting compounds compared with conventional 502.2-type stationary phases.
- Excellent choice for EPA Method 524.2 Revision IV, resolving 2-nitropropane from 1,1-dichloropropanone.
- Equivalent to USP G43 phase.
Filtre
Art.-Nr.: RT-40924
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-40924-6850
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-40925
Mevcut
Art.-Nr.: RT-10968
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10968-284
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10968-6850
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10968-124
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10968-127
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10969
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10969-600
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10969-6850
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10969-124
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10970
Mevcut
Art.-Nr.: RT-10970-101
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10970-1286850
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10970-600
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10970-6850
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10970-125
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10972
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10972-042
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10972-105
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10972-6850
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10972-125
Mümkün olan en kısa sürede tedarik edilecektir
Art.-Nr.: RT-10971
Mevcut
Art.-Nr.: RT-10971-1266850
Mümkün olan en kısa sürede tedarik edilecektir