-
Producten
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Restek MXT GC Columns
-
MXT-1 GC Columns
-
MXT-1HT SimDist GC Columns
-
MXT-5 GC Columns
-
MXT-20 GC Columns
-
MXT-35 GC Columns
-
MXT-50 GC Columns
-
MXT-65 GC Columns
-
MXT-65TG GC Columns
-
MXT-200 GC Columns
-
MXT-502.2 GC Columns
-
MXT-1301 GC Columns
-
MXT-1701 GC Columns
-
MXT-2887 GC Columns
-
MXT-Alumina BOND/MAPD PLOT GC Columns
-
MXT-Alumina BOND/Na2SO4 PLOT GC Columns
-
MXT-BAC1 GC Columns
-
MXT-Biodiesel TG GC Columns
-
MXT-Msieve 5A PLOT GC Columns
-
MXT-Q-BOND PLOT GC Columns
-
MXT-Volatiles GC Columns
-
MXT-WAX GC Columns
-
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Handelsmerken
-
Catalogi en downloads
-
Aanbieding
-
Troubleshooting
100% Dimethyl Polysiloxane
(Siltek®-Treated Stainless Steel)
- Specifically engineered for high-temperature simulated distillation (SimDist) of petroleum products from C5 to C110.
- Reliably meets all performance requirements for ASTM D6352, ASTM D7169, and ASTM D7500, while also supporting applications developed around ASTM D2887, D5307, D7096, and D7213.
- 100% dimethyl polysiloxane stationary phase provides true methyl silicone selectivity, generating the correct retention time/boiling point relationship for accurate boiling point calculations.
- Manufactured from unbreakable Siltek®-treated stainless steel tubing, providing exceptional mechanical durability for demanding laboratory and process environments.
- Stable to 450 °C, exceeding the temperature requirements of high-temperature SimDist methods and delivering exceptionally low bleed with extended column lifetime.
- Excellent peak shape and thermal robustness ensure reliable characterization of medium and heavy petroleum fractions.
- Individually tested to guarantee chromatographic performance and method compliance.
- Compact 7-inch coil diameter allows convenient installation while maintaining reliable performance.
- Compared with MXT-500 SimDist, which utilizes a carborane siloxane polymer and can slightly shift calculated boiling range distributions for aromatic petroleum samples, the MXT-1HT SimDist provides true methyl silicone polarity for direct comparison with conventional SimDist methods and historical datasets.
Filter
Art.-Nr.: RT-70112
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70112-273
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70115-272
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70112-6850M
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70115-272600
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70112-600
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70118
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70118-273
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70118-2731
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70118-2732
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70118-600
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70131
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70134
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70134-273
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70130
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70130-273
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70119
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70132
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70132-6850M
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70132-600
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70133
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70133-6850M
Zal zo spoedig mogelijk worden ingekocht
Art.-Nr.: RT-70133-600
Zal zo spoedig mogelijk worden ingekocht