Produits
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Rt-Alumina BOND/CFC GC Columns
-
Rt-Alumina BOND/MAPD GC Columns
-
Rt-Alumina BOND/KCl GC Columns
-
Rt-Alumina BOND/Na2SO4 GC Columns
-
Rt-Msieve 5A GC Columns
-
Rt-Q-BOND GC Columns
-
Rt-QS-BOND GC Columns
-
Rt-S-BOND GC Columns
-
Rt-U-BOND GC Columns
-
Rt-U-BOND XP GC Columns
-
MXT-Alumina BOND/MAPD PLOT GC Columns
-
MXT-Alumina BOND/Na2SO4 PLOT GC Columns
-
MXT-Msieve 5A PLOT GC Columns
-
MXT-Q-BOND PLOT GC Columns
-
-
Restek MXT GC Columns
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Marques déposées
-
Catalogues & téléchargements
-
Fin de série
-
Troubleshooting
MXT-Alumina BOND/MAPD PLOT GC Columns
The Restek MXT-Alumina BOND/MAPD is specifically engineered for the analysis of petrochemical process streams and downstream products, where reliable determination of trace acetylene, methyl acetylene (propyne), and propadiene (MAPD) is critical. Its optimized alumina deactivation technology delivers exceptional inertness, superior reproducibility, and outstanding sample capacity, enabling accurate trace-level measurements while minimizing peak tailing. Manufactured on Siltek®-treated stainless steel tubing, the column combines excellent mechanical durability with the robust performance required for continuous refinery and process GC applications.
- Alumina PLOT Phase; Optimized MAPD Deactivation (Siltek®-Treated Stainless Steel)
- Specifically designed for the analysis of petrochemicals and downstream products, including ethylene, propylene, butylenes, and butadiene.
- Optimized deactivation technology delivers maximum response for trace concentrations of acetylene, methyl acetylene (propyne), and propadiene (MAPD).
- Highly inert alumina stationary phase provides excellent reproducibility for demanding process GC applications.
- High sample capacity minimizes peak tailing, resulting in improved separation and more accurate quantification of target compounds.
- Extended operating temperature up to 250 °C enables rapid elution of high molecular weight hydrocarbons (up to dodecane) and accelerates column regeneration following exposure to moisture.
- Manufactured from Siltek®-treated stainless steel tubing, providing exceptional mechanical durability for continuous industrial operation.
- Also available as Rt-Alumina BOND/MAPD columns in fused silica for laboratories requiring conventional capillary column formats.
Similar Phases:
No direct equivalent available.
Filtre
1 Produits
MXT-Alumina BOND/MAPD, 30m x 0.53mm ID, 10µm film, ea.
Restek GC Column MXT-Alumina BOND/MAPD, 30 m x 0.53 mm ID, 10 µm film thickness, ea.
Art.-Nr.: RT-79728
EUR 1,623.00
En cours de réapprovisionnement