-
Produits
-
GC Accessories
-
GC Columns
-
Agilent Technologies
-
GL Sciences
-
MEGA
-
Ohio Valley Specialty
-
PerkinElmer
-
Quadrex
-
Restek
-
Restek RMX-5Sil MS
-
Restek Rxi GC Columns
-
Restek Rtx GC Columns
-
Restek Rt GC Columns
-
Restek Wax GC Columns
-
Restek Chiral GC Columns
-
Restek PLOT Columns
-
Restek MXT GC Columns
-
MXT-1 GC Columns
-
MXT-1HT SimDist GC Columns
-
MXT-5 GC Columns
-
MXT-20 GC Columns
-
MXT-35 GC Columns
-
MXT-50 GC Columns
-
MXT-65 GC Columns
-
MXT-65TG GC Columns
-
MXT-200 GC Columns
-
MXT-502.2 GC Columns
-
MXT-1301 GC Columns
-
MXT-1701 GC Columns
-
MXT-2887 GC Columns
-
MXT-Alumina BOND/MAPD PLOT GC Columns
-
MXT-Alumina BOND/Na2SO4 PLOT GC Columns
-
MXT-BAC1 GC Columns
-
MXT-Biodiesel TG GC Columns
-
MXT-Msieve 5A PLOT GC Columns
-
MXT-Q-BOND PLOT GC Columns
-
MXT-Volatiles GC Columns
-
MXT-WAX GC Columns
-
-
Restek Stx GC Columns
-
Restek Fused Silica & Metal Tubings, Guard Columns
-
-
Teknokroma
-
Thermo Scientific
-
Trajan (SGE)
-
VICI
-
-
LC Accessories
-
LC Columns
-
Vials and Accessories
-
Sample Preparation
-
Syringes
-
Instruments
-
Laboratory Supplies
-
-
PAL System
-
GC Column Finder
-
LC Column Finder
-
SPE Finder
-
Reference Standards
-
Marques déposées
-
Catalogues & téléchargements
-
Fin de série
-
Troubleshooting
- Proprietary Crossbond® diphenyl/dimethyl polysiloxane stationary phase specifically optimized for volatile organic pollutant (VOC) analysis.
- Designed for US EPA Method 502.2, US EPA Method 524.2, and numerous gasoline range organics (GRO) methods used for underground storage tank monitoring.
- Excellent selectivity for trihalomethanes, with ideal polarity for the separation of light hydrocarbons and aromatic compounds.
- Low-bleed stationary phase provides dependable performance for both GC-FID and GC-MS analyses while maintaining excellent thermal stability.
- Enables accurate quantification of all target compounds specified in EPA Methods 502.2 and 524.2, whether using GC-MS or PID/ELCD detection systems.
- 105-meter configurations provide sufficient resolving power to separate the light gases specified in EPA methods without requiring subambient cooling.
- Manufactured from Siltek®-treated stainless steel tubing, combining outstanding mechanical durability with excellent chromatographic inertness.
Filtre
Art.-Nr.: RT-70919
En cours de réapprovisionnement
Art.-Nr.: RT-70919-273
En cours de réapprovisionnement
Art.-Nr.: RT-70919-276
En cours de réapprovisionnement
Art.-Nr.: RT-70908
En cours de réapprovisionnement
Art.-Nr.: RT-70908-273
En cours de réapprovisionnement
Art.-Nr.: RT-70908-283
En cours de réapprovisionnement
Art.-Nr.: RT-70908-2731
En cours de réapprovisionnement
Art.-Nr.: RT-70908-102272
En cours de réapprovisionnement
Art.-Nr.: RT-70908-111273
En cours de réapprovisionnement
Art.-Nr.: RT-70910
En cours de réapprovisionnement